BR-1022
Downrange · 10 GHz radars

BR-1022 Doppler Radar System

A continuous-wave X-band Doppler radar system for ballistic targets, with selectable 0.2 W or 2 W transmit power.

29 dBiAntenna gain
10.525 GHz nominal; other frequencies on requestOperating frequency
30 to 3,000 m/s standard; up to 10,000 m/s optionalRadial velocity coverage
Overview

BR-1022 Doppler Radar System

The BR-1022 is a continuous-wave X-band Doppler radar system for velocity measurement and analysis of standard, tracer, base-bleed, APDS/APFSDS, rocket and mortar projectiles from 5.56 mm to 155 mm. It has been extensively field-tested and is recognized for its reliability.

The radar uses a bistatic configuration with separate transmitting and receiving flat-panel microstrip antennas, and a transmitter output selectable between 0.2 W and 2 W to cover both short-range and medium-range measurements. Its sealed magnesium housing is protected against dust and water, and an integrated telescope supports alignment on the line of fire.

For ballistic test teams measuring standard, tracer, base-bleed, APDS/APFSDS, rocket and mortar projectiles at short to medium range.

Images
Performance & specifications

Technical facts.

DatasheetNo document available at the moment
Radar
Radar band / modeX-band, continuous-wave Doppler
Antenna configurationBistatic, separate transmitting and receiving flat-panel microstrip antennas
Antenna gain29 dBi
Beamwidth (vertical × horizontal)4° × 4°
PolarizationVertical; horizontal optional
Transmitter output power0.2 W or 2 W, selectable; higher power optional
Transmitter sourcePhase-locked DRO, CW
Phase noise−110 dBc/Hz at 10 kHz offset
ModulationNone
Operating frequency10.525 GHz nominal; other frequencies on request
Humidity0 % to 100 % relative humidity, operating and storage
Performance
Supported calibre range5.56 mm to 155 mm
Velocity measurement accuracy± 0.05 %
System precision± 0.1 %
Receiver noise figure< 1.8 dB
Radial velocity coverage30 to 3,000 m/s standard; up to 10,000 m/s optional
Physical & power
Operating temperature−20 °C to +55 °C
Storage temperature−30 °C to +55 °C (in the supplied transport case)
Power supply115 VAC, 60 Hz, 1.0 A or 230 VAC, 50 Hz, 0.5 A
Dimensions83 cm × 45 cm × 10 cm
Weight21 kg (without yoke)
ApprovalsFCC
Range performance
5.56 mm (−50 dBsm RCS)510 m typical / 610 m maximum
7.62 mm (−45 dBsm RCS)700 m typical / 830 m maximum
155 mm (−11 dBsm RCS)> 3,300 m typical / 4,600 m maximum
Operating notes
  1. The acquisition chain runs indoors: the JB-6e conditions and digitizes the radar signals and sends them to TestCenter 7 over Ethernet. The standard complete set includes the radar antenna with its alignment telescope, JB-6e, TestCenter 7 licence, AT-01 with trigger cable, antenna cables, tripod, accessories and user documentation.
  2. Typical range is computed with an FFT size of 1024 and maximum range with an FFT size of 2048, both with a 10 dB minimum signal-to-noise ratio, in 2 W transmit mode, at 10.525 GHz and assuming a flat trajectory with the radar viewing the projectile base. For the 5.56 mm, Infinition uses a conservative RCS of −50 dBsm; with the −47 dBsm NATO reference value, 5.56 mm ranges are about 20 % longer.
  3. Values marked > are deliberately limited: at long range the projectile is no longer seen from its base and the published range is capped accordingly. These are calculated sensitivity limits, not guaranteed values: actual performance varies with projectile shape and material, trajectory profile, radar alignment and test conditions.
  4. Available options: TestCenter 7 Advanced (drag analysis module), OT-01 optical trigger, AT-02 trigger for low-noise and subsonic shots, and the in-bore measurement module. For longer ranges, Infinition also offers the 15 W BR-29015 and the long-range BR-33030.
Product documents

Downloads.

Technical brochures and product documents for configuration and review.
PDFNo document available at the momentBR-1022 · Contact us to receive the documentationRequest
Related

Other products in this category.

Explore related Infinition systems designed for the same measurement condition.