AT-01
Triggering · Trigger device

AT-01 Acoustic Transducer

An acoustic transducer for triggering data acquisition in Doppler radar systems.

±3 VOutput signal
1.0 kgWeight
Overview

AT-01 Acoustic Transducer

The AT-01 is an acoustic trigger that provides the time-zero reference for Infinition Doppler radar systems. Placed close to the muzzle, it detects the very strong pressure wave generated by a firing and sends a trigger signal to the acquisition system, which starts the recording and anchors the time axis of every result.

It combines a piezoelectric pick-up with a built-in amplifier in a rugged brass enclosure, for long cable runs and use extremely close to the muzzle. Power and signal share the same cable, so a simple coaxial cable can be used. It is the standard trigger supplied with Infinition radar systems and the recommended choice for most applications, from small arms to medium calibre.

For teams that need an acoustic time reference to trigger acquisition in an Infinition Doppler radar chain.

Images

AT-01 in detail.

Performance & specifications

Technical facts.

Download full datasheetPDF · 790 KB · AT-01
Signal & interface
SensorPiezoelectric pick-up with built-in amplifier
DetectionMuzzle-blast shock wave
Output signal± 3 V, analog differential
Typical trigger level0.5 V (TestCenter 7)
Trigger delayComputed by software from the speed of sound
Sensitivity adjustmentNone, threshold set by software
CompatibilityJB-6e junction box, BR-2401 integrated acquisition and all Infinition radar systems operated with TestCenter 7
Physical & power
Power supply12 V, 2 mA, power and signal on the same cable
Operating temperature−20 °C to +50 °C
EnclosureHeavily rugged brass enclosure, manufactured by Infinition
MountingStandard photo tripod, 1/4-20 screw
Weight1.0 kg
CablesTrigger cables of 20, 50, 75 and 100 m, with or without cable reel
Operating notes
  1. No sensitivity adjustment is required: the threshold is set by software, typically 0.5 V in TestCenter 7. The analog differential output improves immunity to environmental electrical noise, and the unit mounts on a standard ¼-20 photo tripod.
  2. TestCenter 7 compensates the acoustic delay automatically: its Acoustic Transducer Delay Calculator uses the muzzle-to-sensor distance and the air temperature, so time zero matches the true muzzle exit. The compensation assumes the supersonic shock wave at muzzle exit; for subsonic projectiles and other low-noise shots, the AT-02 trigger is available.
  3. Recommended distance from the muzzle: a few centimetres for small calibres (5.56 mm, 7.62 mm), 30 to 60 cm for medium calibres (12.7 mm, 20 mm), and up to 1 m maximum for large calibres and artillery (105 mm and above). For very large artillery, where acoustic detection is no longer reliable, the OT-01 optical trigger is the right choice.
  4. Trigger cables are available in 20, 50, 75 and 100 m lengths, with or without cable reel. The AT-01 is supplied with its tripod mounting head.
Measurement chain

Complete the measurement chain.

Identify the system role, then request the configuration appropriate to the range, projectile, acquisition, and analysis conditions.
Infinition Doppler radar systems
Product documents

Downloads.

Technical brochures and product documents for configuration and review.
Related

Other products in this category.

Explore related Infinition systems designed for the same measurement condition.